The SC-Monolith 2 POWER/DMX consists of a 3 x 1,50 mm² power cable and two DMX 512 lines. Each DMX wire pair is shielded by a tinned helical copper mesh. The power cable was developed in compliance with VDE and has its own jacket for extra safety.
Of course the AES/EBU cable can also be used as a microphone cable or as a feed line for active loudspeaker systems.
Advantages:
- Parallel control for lighting boards through one cable via power line and DMX signal
- Very flexible and enormously tread-resistant due to the round jacket made of cotton and viscose
- Very good pairwise shielding of the DMX lines due to tinned helical copper mesh screen or copper braiding
Application:
- Control line for DMX lighting consoles (wave impedance of 110 O)
- Analogue + digital audio multipair with power supply
Specifications:
| Article number | 500-0051-2 |
|---|---|
| Name | SC-Monolith 2 |
| EAN | 4049371003797 |
| Properties | Analog |
| Properties | Digital 110 O AES / EBU |
| Properties | OFC oxygen free copper |
| Application area | Mobile outdoor / indoor |
| Application area | Stage / live |
| Application area | Installation |
| Application area | Studio / Broadcast |
| Application | DMX & Power |
| Colour | black |
| Colour detailed | black |
| Signal transmission | symmetrical |
| Construction | (3LIY1,5mm²)Y+ 02(2LI2Y0,14mm²)DYVLY |
| Construction (power) | (3LIY1,5mm²)Y |
| Construction (AES/EBU, DMX) | 02(2LI2Y0,14mm²)DY |
| Jacket material | PVC |
| Jacket Ø mm | 12,30 |
| Jacket Ø (power) mm | 6,20 |
| Jacket Ø (AES/EBU, DMX) mm | 3,00 |
| Number of Channels (power) | 1 |
| Number of Channels (AES/EBU, DMX) | 2 |
| Inner conductor (power) | 3 |
| Inner conductor (AES/EBU, DMX) | 2 |
| Inner conductor (power) mm² | 1,50 |
| Inner conductor (AES/EBU, DMX) mm² | 0,14 |
| Inner conductor Ø (power) mm | 1,38 |
| Inner conductor Ø (AES/EBU, DMX) mm | 0,42 |
| AWG (power) | 15 |
| AWG (AES/EBU, DMX) | 25 |
| Shielding (AES/EBU, DMX) | Copper spiral, tin-plated |
| Shielding factor % | 90 |
| Copper strands (power) | 28 |
| Copper strands (AES/EBU, DMX) | 36 |
| Copper strand Ø (power) mm | 0,25 |
| Copper strand Ø (AES/EBU, DMX) mm | 0,07 |
| Wire insulation material (power) | PVC |
| Conductor insulation Ø mm | 0,00 |
| Conductor insulation Ø (power) mm | 2,30 |
| Conductor insulation Ø (AES/EBU, DMX) mm | 1,15 |
| Weight per 1 m g | 200 |
| UV-resistant | yes |
| Fire load per m kWh | 0,86 |
| Style variant | round |
| Packing | bulk stock |
| Temperature min. °C | -30 |
| Temperature max. °C | 70 |
| Width mm | 12,3 |
| Height mm | 12,3 |
| Capac. cond./cond. per 1 m (AES/EBU, DMX) pF | 52 |
| Capacity wire/wire at 1 ft. (AES/EBU, DMX) pF | 15,8496 |
| Capac. cond./shield. per 1 m (AES/EBU, DMX) pF | 89 |
| Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) pF | 27,1272 |
| Impedance O | 110 |
| Surge impedance (AES/EBU, DMX) O | 110 |
| Insulation resist. per 1 km GO | 0 |
| Insulation resist. per 1000 feet GO | 0 |
| Insulation resist. per 1 km (AES/EBU, DMX) GO | 0,1 |
| Insulation resist. per 1000 feet (AES/EBU, DMX) GO | 0,0305 |
| Conductor resistance per 1 km O | 0 |
| Conductor resistance per 1000 ft. O | 0 |
| Conductor resistance per 1 km (power) O | 80 |
| Conductor resistance per 1000 ft. (power) O | 24,384 |
| BPVo-Euroclass | Fca |